7KW DUAL-MODE BACKUP GENERATOR
Operator’s Manual
Manual del Operario
Manuel d’utilisation
SAVE THESE INSTRUCTIONS
Manual No. 200267GS
Revision A (06/26/2006)
Model / Modelo/ Modèle
040248
Failure to read and follow the operator’s
manual and all operating instructions can
result in death, bodily injury, and/or
property damage.
WARNING
L’omission de lire et de suivre le manuel de
l’utilisateur et toutes les directives d’utilisation
pourrait entraîner la mort, des blessures
corporelles ou des dommages matériels.
AVERTISSEMENT
Si no se leen y siguen las indicaciones del
Manual del operario y todas las instrucciones
de uso, se pueden producir daños materiales,
lesiones o incluso la muerte.
ADVERTENCIA
Home Generator Systems
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - SAVE THESE INSTRUCTIONS

7KW DUAL-MODE BACKUP GENERATOROperator’s ManualManual del OperarioManuel d’utilisationSAVE THESE INSTRUCTIONSManual No. 200267GSRevision A (06/26/2006

Page 2

8www.briggsandstratton.comLP Fuel Tank InstallationIMPORTANT: To ensure optimal performance,use two (2) LP fuel tanks during operation.This section de

Page 3 - Table of Contents

3. Using a sponge, rag or small non-metallic brush, applythe soap water mixture at each of the locationsshown in Figure 10 below.4. Check each locatio

Page 4

10www.briggsandstratton.com8. Repeat Steps 2 through 7 until no leaks are detected.DO NOT use the generator if leaks cannot bestopped. Contact a quali

Page 5

11Generator Controls and FeaturesRead this Operator’s Manual and safety rules before operating your generator.Compare the illustrations with your gene

Page 6 - Equipment Description

12www.briggsandstratton.comGFCIMAIN BREAKERPUSHTORESETControl Panel Controls and FeaturesCompare this illustration with your generator’s Control Panel

Page 7

13Receptacles120/240 Volt AC, 30 Amp, LockingReceptacleThis receptacle (Figure 11) supplies the entire generatoroutput and is protected against overlo

Page 8 - Assembly/Installation

14www.briggsandstratton.comOperating Your GeneratorStarting the EngineUse the following start instructions:1. Make sure unit is on a flat, level surfa

Page 9 - Attach Tank Hold-Down Rod

15Ground Fault ProtectionThis unit is equipped with a Ground Fault CircuitInterrupter (GFCI). This device meets applicable federal,state and local cod

Page 10

16www.briggsandstratton.comDon’t Overload GeneratorCapacityYou must make sure your generator can supply enoughrated (running) and surge (starting) wat

Page 11 - Leak Testing Fuel System

17Maintenance ScheduleFollow the hourly or calendar intervals, whichever occurs first.More frequent service is required when operating in adverse cond

Page 12 - Battery Connection

Briggs & Stratton Power Products Group, LLC900 North ParkwayJefferson, WI 53549Copyright © 2006 Briggs & Stratton Power Products Group, LLC.A

Page 13

18www.briggsandstratton.comEngine parts should be kept clean to reduce the risk ofoverheating and ignition of accumulated debris. Use thesame instruct

Page 14

19Service Air Cleaner ElementsYour engine will not run properly and may be damaged ifyou run it with dirty air cleaner elements.• Replace the air clea

Page 15 - Equipment Ground

20www.briggsandstratton.comIMPORTANT: DO NOT use pressurized air or solventsto clean cartridge. Pressurized air can damage cartridge;solvents will dis

Page 16 - Operating Your Generator

21Service BatteryIf it is necessary to service the battery, proceed as follows:1. Open control panel cover.2. Remove the 15 Amp fuse from the control

Page 17 - Ground Fault Protection

22www.briggsandstratton.comNotesTroubleshootingProblem Cause CorrectionEngine is running, but no ACoutput is available.1. Circuit breaker open or defe

Page 18 - Don’t Overload Generator

23Replacement PartsReplacement parts are available from your authorizedBriggs & Stratton Service dealer. Each one carries a stockof genuine Briggs

Page 19 - Maintenance Schedule

24www.briggsandstratton.comBriggs & Stratton Corporation (B&S), the California Air Resources Board (CARB)and the United States Environmental P

Page 20

253. No ChargeRepair or replacement of any Warranted Part will beperformed at no charge to the owner, includingdiagnostic labor which leads to the det

Page 21 - Service Air Cleaner Elements

26www.briggsandstratton.comThe warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for t

Page 22

1Table of ContentsSafety Rules...2Equipment Description...

Page 23 - Service Battery

2www.briggsandstratton.comSAVE THESE INSTRUCTIONSSafety RulesThis is the safety alert symbol. It is used toalert you to potential personal injuryhazar

Page 24 - Troubleshooting

3• DO NOT touch hot surfaces and avoid hot exhaust gases.• Allow equipment to cool before touching.• Keep at least 5 ft. (152 cm) clearance on all sid

Page 25 - Product Specifications

4www.briggsandstratton.comEquipment DescriptionRead this manual carefully and becomefamiliar with your generator. Know itsapplications, its limitation

Page 26

5Ground Fault ProtectionThe generator’s receptacles are equipped with GroundFault Circuit Interrupter (GFCI) protection. This GFCIdevice meets applica

Page 27

Generator LocationConsider these factors when determining the propergenerator operating location:• Install the unit outdoors on a flat, level surface

Page 28 - WARRANTY PERIOD

7• Install the unit in a location where sump pumpdischarge, rain gutter down spouts, roof run-off,landscape irrigation, or water sprinklers will not f